![](https://img.alicdn.com/imgextra/i3/33904207/O1CN01cvJFHm1gwqrhEBrWs_!!33904207.jpg)
![](https://img.alicdn.com/imgextra/i3/33904207/O1CN01DDOXGC1gwqrjOkXY8_!!33904207.jpg)
![](https://img.alicdn.com/imgextra/i1/33904207/O1CN01ynCarF1gwqrnj481e_!!33904207.jpg)
![](https://img.alicdn.com/imgextra/i1/33904207/O1CN01T30OJV1gwqrqeC3Ez_!!33904207.jpg)
Features:
German design and production, free one-year warranty
4 digital inputs
- 1)Digitally balanced (AES 3/11), up to 24/192KHZ
- 2)Coaxial (S/P-DIF), support up to 24/192KHZ
- 3)Optical TOS Link, support up to 24/192 KHZ
- 4)USB, up to 24 / 192 kHz A-B port
Product parameters:
Analog input: 2X XLR, impedance 110 ohms
bandwidth: 10HZ-20KHZ(-0.1db)
10HZ-70KHZ(-1db)
Sensitivity> 119db(A-wtd)
THD Total Harmonic Distortion:<-112dB(@ -1 dBFs)
Dimensions: 168x49x117MM(W x H x D)
Official website introduction: http://www.violectric.de/produktdetails/dac_rs_06.html
USB driver download address: http://www.violectric.de/software.html?file=tl_files/Standard_Theme/downloads/Software/Violectric_DriverSetup_v3.0.0.exe
RS06 decoder menu settings and adjustment methods:
1. Enter the setting menu, the method is to press and hold the Resampling button for 2 seconds, the ON key will start flashing.
2. Whether the indicator light below BAL is on means the digital filtering mode is sharp roll-off or soft roll-off. Lighting means soft roll-off, and no light means sharp roll-off. Switching is done by pressing the input selection button once.
3. After setting the digital filter mode, press the Resampling button once to enter the next menu: phase adjustment. The indicator light under the Coax is lit to indicate 180-degree reverse phase adjustment, and no light indicates that the phase is not adjusted. Switching is done by pressing the input selector once.
4. After setting, press and hold the Resampling button for 2 seconds to exit the menu setting mode.
RS06 decoder analog output level setting method:
1. Press and hold the input selection button for 2 seconds to enter the setting mode. The blue LOCk indicator starts flashing.
2. At this time, the 4 indicators on the left side of the LOCK indicator represent the set analog output level. One light is on for +3dBu, two lights on for +9dBu, three lights on for +15dBu, and four lights on for +21dBu. The above numbers all refer to the level of the balanced output port, and the output level of the unbalanced port is -3, +3, +9, +15 correspondingly.
3. The way to change the analog output level is to short press the input selection button on the left, or the Resampling button on the right.
4. After setting, press and hold the input selection button for 2 seconds to exit the setting mode.