CT-9809 short circuit, open circuit, misplacement wire tester display: |
Wire tester fixture(40pin at one end, 80pin at both ends, suitable for USB data line, RS232 communication line and pitch: 2.00mm, 2.54mm, 3.96mm and 5.08mm wire):
Instructions for use of CT-9809 wire tester: |
1. Application:
SHEN HWA CTThe -9809 wire tester is suitable for testing the electrical quality of electronic cable products such as terminal wires, USB, computer peripheral wires, flat wires, etc., which have terminals at both ends and can be fully connected in the production process, and can be quickly tested Bilateral wiring harness short circuit, open circuit, dislocation and other electrical characteristics, it is a newest and fast economical bilateral wiring harness tester.
2. Technical specifications:
1. Working voltage:AC220V+/-10% 50Hz, the instrument can work continuously
2. Test points: A end: 40Pin, B end: 40Pin
3. Description of each component:
4. Operation steps:
1. Connect the power supply and turn on the power switch on the back. The power indicator light is on and the READ DATA? PUT CABLE ON(Read data? The wire is empty)
2. Insert 40P cables at the A and B ends, and connect the test fixture of the wire to be tested;
3. Insert the wires to be tested into ends A and B respectively, and confirm that all the points of the wire harness at both ends are well connected;
4. Press the “read button” after the learning is completed, and then press the “read button” to view the connection data after reading the line data, the screen will appear LINE, A: * TO B: *, every time you press the “read” key once, you can only view one set of wiring data until you finish viewing it;
5. After reading the wire correctly, dial the wire to start the test. The instrument does not need to repeat the “read” key during continuous testing, and the test can be performed automatically, and the screen will display “PASS” and& ;ldquo;Beep”, it means good product.
6. If there is a short circuit during the test, open circuit, the screen will appear “ERROR:OPEN, A:** B:**”The error red light will be on, and there will be no sound at the same time. Indicates that the wire is defective(OPEN means open circuit, SHORT means short circuit, and LOCATION means misalignment).
Five, matters needing attention:
1. This instrument is suitable for standard testing(That is, the wires with terminals on the A and B ends, and both sides can be tested)
2. When the test is abnormal, you can use the probe to find a point to check whether the fixture is intact
3, The instrument should be clean and hygienic, and the operation surface should be tidy and clean. In case of sudden power failure, the power should be turned off in time
4. In case of any failure in the setting, the technical service department of our company must be notified in time, and it is not allowed to start repairs without authorization.
six,Attachment: manual,2 sets of cables, Four pin headers, 1 test lead wire.
Note: The product can be invoiced, if you need to invoice, you can contact the shopkeeper, or call: Mr. Zhong, 18929393937. This machine cannot test single-ended wires or wires with vacant pins. Both double-ended wires can be tested(One end does not exceed 40PIN), No need to set up, press the read button after connection, the instrument will automatically memorize the wiring method of the wire, you can test, and you can test directly when you test the same wire again!
Simple test steps of CT-9809 wire tester: |
Turn on the CT-9809 wire tester: |
CT-9809 wire tester test case: install the cable and pin header to read the wiring method of the sample wire: |
CT-9809 wire tester passed the test and displays PASS and the green light is on, the instrument has a beep to remind: |
CT-9809 wire tester wire break(Open)Display OPEN, and display the corresponding pin position: |
CT-9809 wire tester wire short circuit shows SHORT, dislocation shows LOCATION: |
Remarks: The above test cases only show the test of 4pin wire. The instrument can test more types of wires. For further information, please contact customer service or call: 0755-66690752 or: Mr. Zhong 18929393937.