Features:
Designed and made in Germany, licensed by Anrun, one year free warranty
4 digital inputs
- 1)Digital balance (AES 3/11), support up to 24/192KHZ
- 2)Coaxial (S/P-DIF), support up to 24/192KHZ
-3)Optical TOS Link, support up to 24/192 KHZ
-4)USB, support to 24/192 kHz A-B port
Product parameters:
Analog input: 2X XLR, impedance 110 ohm
bandwidth:10HZ-20KHZ(-0.1db)
10HZ-70KHZ(-1db)
Sensitivity> 119db(A-wtd)
THD total harmonic distortion:<-112dB(@ -1 dBFs)
Size: 168x49x117 MM(W x H x D)
Official website introduction: http://www.violectric.de/produktdetails/dac_rs_06.html
USB driver download address: http://www.violectric.de/software.html?file=tl_files/Standard_Theme/downloads/Software/Violectric_DriverSetup_v3.0.0.exe
RS06 decoder menu setting and adjustment method:
1. Enter the setting menu by pressing and holding the Resampling button for 2 seconds, the ON key will start to flash.
2. Whether the indicator light below BAL is on indicates that the mode of digital filtering is sharp roll-off or soft roll-off. Lit means soft roll-off, unlit means sharp roll-off. The switching method is to press the input selection button once.
3. After setting the digital filter mode, press the Resampling button once to enter the next menu: phase adjustment. The indicator light below Coax lights up to indicate the 180-degree phase reversal adjustment, unlit indicates that the phase is not adjusted. The switching method is to press the input selector button once.
4. After setting, long press the Resampling button for 2 seconds to exit the menu setting mode.
RS06 decoder analog output level setting method:
1. Long press the input selector button for 2 seconds to enter the setting mode. The blue LOCk indicator light starts to flash.
2. At this time, the 4 indicators on the left side of the LOCK indicator represent the set analog output level. One light on means +3dBu, two lights on means +9dBu, three lights on means +15dBu, and four lights on means +21dBu. The above figures refer to the level of the balanced output port, and the output level of the unbalanced port is -3, +3, +9, +15.
3. The method to change the analog output level is to short press the input selector button on the left or the Resampling button on the right.
4. After setting, press and hold the input selector button for 2 seconds to exit the setting mode.
...........